国产综合日韩另类一区二区專業從事互動視頻_疯狂撞击美妇雪白的大肉臀_2019中文字字幕永久在线_久久天天躁狠狠躁夜夜电影_欧美成人性色生活片_一本大道香蕉高清视频_欧美国产精品第一区_亚洲欧洲无码?V不卡在线_日本在线视频免费播放_日韩精品人妻中文字幕有码

Shanghai Guangchun balance machine Manufacturing Co., Ltd.
LOCATION:Home > News > Light spring dynamics

News

The calculation formula for the residual unbalance

Time:2018-02-05Number:494

The calculation formula for the residual unbalance:

Uper=M.e=m.r=

Balancing machine selection steps:

1. According to the rotor (workpiece) is required to double-side calibration or single-side calibration to primary choose of the balance machine.

When the length and diameter ratio of the rotor is > 0.2, choose double-sided balancing machine .On the contrary, choose single - sided balance machine.

2. If the rotor is determined to be double-side calibration or single-side calibration, the balance machine can be further determined by the maximum diameter, maximum length and weight of the rotor.



3. Comparing the residual unbalance of the rotor (Uper) with the minimum achievable ucbalance (Umar).


A) when Uper > Umar, the balance machine is selected correctly. The rotor Uper value can be calculated according to the previous calculation formula, and the balance machine cannot be selected correctly without the Uper value .

B)When the minimum Umar> Uperindicating that the existing universal balance machine cannot meet the rotor balance requirements, it needs to be redesigned or changed into a special balancing machine.


C) Sometimes the supporting mode of the rotor is special and the balancing machine needs to be changed.